ExtractBlock is not able to extract block with identical names
ExtractBlock let user select block to extract but if the block of the same name, all blocks will be extracted.
Steps to reproduce:
- Open samename.vtm, Apply
- Filters -> ExtractBlock
- Select a single block, apply
- All blocks are extracted
================= Original issue below:
Hi,
I am trying to use paraview to process the results of the Fire Dynamics Simulator (FDS). Recently, a new reader has been implemented in paraview and I am trying to use it.
I set a simple case of a convective heat transfer with slides defined by FDS. When I try to process the results the reader can see the different temperature slices but I can’t select only one, they are all selected, even though I click on only one “STRUCTURE_TEMPERATURE” (see image).
It seems that the name of the blocks from the smv are all the same.
See the discussion : https://discourse.paraview.org/t/fdsreader-vtkpartitioneddatasetcollection/13599
Could it be possible to change the name, maybe including the coordinate of the slide ?