Prism Unit conversion file is not read except for 300 series tables
This issue was created automatically from an original Mantis Issue. Further discussion may take place here.
The prism unit conversions read the actual conversions factors from an xml file, by default named SESAMEConversions.xml. There is a separate conversions for each table. In the default file (in the ParaView source directory with the Prism Client code under plugins) there is only one set of conversions, for 301 tables. Other tables are read but no unit conversions are applied.
I have a much more complete conversions file, but when I point a nearly 3.10.0 ParaView at it, it does not properly apply the new conversions so no surfaces are displayed. Since this is worse than displaying the surface without conversions, I would prefer not to commit or distribute the new conversions file until this is fixed.
Note that a user is interested in this capability and not having the correct conversions is a significant obstacle.
I have a non-distributable test data set and am working on one for unlimited release.