File Series Reader does not update extents
This issue was created automatically from an original Mantis Issue. Further discussion may take place here.
When using a series reader, the output extent of each of the files in the series is the same even if all of the files in the series do not actually have the same extent. It seems like there is an assumption made somewhere that all of the images will have the same extent. The steps to reproduce using the attached archive are:
// Broken
- Open the BlankedCorrelation image in Paraview and change to a 3D view
- Open the BestPatch_* images as a series.
- Click "Next frame"
- Observe that the second patch is in the same position as the first (this is incorrect, they are supposed to be in different positions)
// Works properly 5) Delete the BestPatch_* from the pipeline 6) Open BestPatch_0000 and BestPatch_0001 separately. 7) Observe that they are in different positions (as they are supposed to be).