- 25 Oct, 2019 1 commit
-
-
Jeff Webb authored
Added damping to pleural cavity venous effects (mainly from pneumothorax) and tweaked bilateral pneumothorax scenario timing to prevent error from heavily diseased patient.
-
- 24 Oct, 2019 4 commits
-
-
Jeff Webb authored
Added outputs to pneumothorax scenarios.
-
Jeff Webb authored
Update scenarios with PulmonaryResistance data request. Tweaks to respirtory system validation data.
-
Jeff Webb authored
Hardening respiratory compliance calculation to handle ~0 pressure.
-
Aaron Bray authored
-
- 23 Oct, 2019 3 commits
-
-
Jeff Webb authored
Random tweaks and update to chest wall compliance calculation to prevent weirdness with conscoius respiration.
-
Aaron Bray authored
-
Aaron Bray authored
FYI - RespiratoryDriver test is not working at this point
-
- 22 Oct, 2019 2 commits
-
-
Aaron Bray authored
Fix testing for new patient setup
-
Aaron Bray authored
Adding a SEPatient object for the initial patient (healthy stabilized values)
-
- 21 Oct, 2019 1 commit
-
-
Jeff Webb authored
Updated respiratory and anesthesia machine circuit diagrams. Updated some data flow diagrams. Tweaked some main page verbiage.
-
- 16 Oct, 2019 1 commit
-
-
Aaron Bray authored
-
- 15 Oct, 2019 1 commit
-
-
Jeff Webb authored
Tune pneumothorax CV effects.
-
- 11 Oct, 2019 1 commit
-
-
Jeff Webb authored
-
- 09 Oct, 2019 5 commits
-
-
Aaron Bray authored
(cherry picked from commit 13c44737)
-
(cherry picked from commit 0ebeb6a5)
-
Cleaned up the barorector functionality a bit and commented out the sedation dampening effect until I have better validation data. (cherry picked from commit 8ba9907c)
-
Created a member variable for the mean pressure patient baseline so that I only change the baroreceptor setpoint. Shifted the UpdateBaroreceptorThreshold function to before calculating the total baroreceptor setpoint at each timestep. (cherry picked from commit 6a487e14)
-
Added baroreceptor functionality for second order effects, the baroreceptors become less responsive to the blood pressure changes as time passes. Sedation level dampening of the parasympathetic and sympathetic curve slope. (cherry picked from commit d3668021)
-
- 30 Sep, 2019 7 commits
-
-
Aaron Bray authored
-
Small fix to action log output.
-
Updated the anesthisia machine circuit to use pressure sources for supplying gases, rather than flow sources. Flow sources cause weird pressures in systems that also include pressure sources.
-
Added some new respiratory specific scenarios. Removed end tidal co2 from stabilization criteria.
-
-
Updated some general math exponentail functions.
-
Aaron Bray authored
-
- 23 Sep, 2019 3 commits
-
-
-
-
Aaron Bray authored
-
- 20 Aug, 2019 2 commits
-
-
Aaron Bray authored
-
Aaron Bray authored
-
- 14 Aug, 2019 1 commit
-
-
Aaron Bray authored
-
- 08 Aug, 2019 2 commits
-
-
Aaron Bray authored
-
Jeff Webb authored
Updated respiratory compliance methodology. Added new respiratory system data setting and definitions. Added a new circuit test for adding volume and changing pressure on a compliance node.
-
- 07 Aug, 2019 2 commits
-
-
Aaron Bray authored
-
Aaron Bray authored
-
- 02 Aug, 2019 1 commit
-
-
Jeff Webb authored
-
- 01 Aug, 2019 2 commits
-
-
Jeff Webb authored
Small tweak to respiration rate in system validation spreadsheet.
-
Rachel Clipp authored
Corrected the pulmonary vascular resistance and pulmonary vascular resistance index equations. Also corrected the Cardiovascular validation table to reflect an accurate value for pulmonary vascular resistance index. Previously calculated value was miscalculated.
-
- 31 Jul, 2019 1 commit
-
-
Aaron Bray authored
-