Unstructured CAM reader has artifacts
This issue was created automatically from an original Mantis Issue. Further discussion may take place here.
We are getting artifacts (bad cells) with the Unstructured CAM reader.
- Local server, Master, Linux.
- Open file f1850_arm30x8_rel06.cam.h3.0002-06-25-00000-Do-Not-Release.nc. Default reader. Connectivity File Name: arm_30_x8_lowconn.g_latlon-Do-Not-Release.nc. Single Level On, Cell Layer Right, Off. Apply.
- Wireframe. Paint by TMQ or FLNT.
<> Notice that there are some cells that go all the way across the mesh. Something is wrong with the reader at the left and right edges.
Including a screenshot. The horizontal lines are the problem.
Utkarsh - ask me for this dataset. Note to self - MT, g drive, on Linux.