IOSS reader is changing variable names to lower case
The new IOSS reader or library is changing variable names to lower case from whatever they originally used. I believe this is a bug. An example, from a user, is using T to represent temperature, and t to represent time. As T becomes t in ParaView (including output screenshots and 2d plots), it is confusing to users. By the way, I verified the cases using seacas explore tool.
Here is how to replicate.
-
5.9.1, Linux (or Mac), builtin server.
-
Open bake.e. All vars on. Apply. (Utkarsh will have this, it is UUR.)
-
Look at, and paint by T. This is correct.
-
5.10.0, Linux (or Mac), builtin server.
-
Open bake.e. Apply.
-
Look at, and paint by t. This is incorrect.