Properties tab shows properties of output port 0 only
This issue was created automatically from an original Mantis Issue. Further discussion may take place here.
If a reader/filter has multiple output ports and you try to connect another filter to any output port other than output port 0, the pipeline gets connected to the correct output port but the properties tab allows changing properties based on output port 0 only.
To reproduce,
- Tools->Manage Plugins->SLACTools->Load Selected
- File->Open->ParaViewData/SLAC/pic-example/mesh.ncdf
- Select SLAC mesh from the dialog
- In Properties tab, check all the first two checkboxes.
- Apply
- Observe in the Information tab, the first output(External Surface) has 6 blocks in the multiblock dataset and second output(Entire volume) has 4.
- Select Entire Volume.
- Filters->Alphabetical->ExtractBlock
Observe that in the Properties tab of Extract Block, where we need to select which blocks to extract, it shows 6 blocks that belong to the first output(External Surface) whereas the ExtractBlock filter is connected to the second output port.